The outage that ran from yesterday afternoon till mid way though today has been resolved. The cause was a defective cable used to connect the main backhaul radio to it's antenna. The cable's factory-crimp was not done correctly, resulting in water infiltration into the cable and connector, cutting signal to below the minimum threshold. The cable, radio, and antenna have all been replaced.